OPC Server Modnet
Marcom OPC Server Modnet for Modbus TCP and RS485/232 networks. Support multi connection, advanced diagnostic functions.
Marcom OPC Server Modnet to communicate with a single product with devices on TCP or RTU protocol!
An OPC Server of the last generation developed in technology .NET Framework 4.6.2.
The Marcom OPC Server Modnet is the ideal tool to connect the field devices with Ethernet interface MODBUS or MODBUS RTU to control or supervision systems.
Is available the download of a time-limited version (30 minuts of runtime) for the complete test of the product.
The product is supplied with a licensing system that adapts to all needs: license 50 variables, license 500 variables, license 1000 variables and license unlimited variables. Is always possible to upgrade to a higher category license.
References of applications created regard the following equipment: Wago 841,842 an RTU. Eletrex Ethernet meters and RTU.PLC S7200 via RTU. PLC Seneca ZTWS Ethernet and RTU. Clivet via RTU. trough MOXA TCP converter to PLC. through Lantronix converter to PLC. to RTU for the integration in Labview.
The main features of OPC Server are:
Link / Connections | to more devices through Ethernet (TCP, UDP) or RS232 / RS422 / RS485 network |
Configuration | Intelligent configurator with automatic address syntax errors |
OPC specification | Compliant with OPC Data Access 2.04 specification |
Traffic analysis | Analysis and recording of data exchanged on the network (performance analysis) Diagnostic of communication at the level of OPC variables |
Type of data supported | 16-bit signed integer 16-bit unsigned integer 32-bit signed integer 32-bit unsigned integer 64-bit signed integer 64-bit unsigned integer 32-bit real 64-bit real Boolean BCD Unsigned Measurement Values Signed Measurement Values String Values Management variables of Boolean type for the area holding register and input register, with the methodology Read-Modify-Write |
Support non standard devices | Support the management of "blocks" complex variables, such as for example used by the Thytronic© protections. |
Additional features | Possibility of scaling of the variables presented at the OPC level Possibility of data swap at byte, word, double word Support block transfer with settable size to optimize communication Import/Export of created configurations Optimized communication speed for serial protocol RTU Write variables from the configuration window of the OPC Server |
Supported operating systems | Compatible with Windows 7/8/10/11 (32 bit and 64 bit) + .NET Framework 4.6.2. |
For more information visit OPC Support