HUR Series Modbus Remote Input/Output (I/O) Devices are designed for facilities of rugged industry and infrastructure.
HUR Series Modbus Remote I/O Devices are tailored to perform various features such as wide temperature, wide range power input range... etc.
HUR Series Modbus Remote I/O Devices offers different I/O combinations, which provide greater flexibility and are compatible with many different applications that makes them the perfect choice for establishing a cost-effective remote I/O system.
HUR Series can be selected in serial interface RS485 for Modbus RTU connection or with ETH interface for Modbus TCP connection.
Main Products
HUR118
- 8 Channel 5-275V AC-DC, 100mA Digital Optocoupler Output
- 5-48V (max. 60V) DC wide range power input
- Device Address changeable with Modbus RTU commands
- Output Values can be saved and Applied After Auto Restart
- Output Configuration for device power up can be defined by user with Modbus Commands
- Easy to Monitor Device Parameters such as Device Up Time, Modbus RTU read counter etc.
- Supports Modbus RTU Protocol over RS485 with 115200 8N1 Data Type
- Easy Firmware Upgrade over Serial Line
- Wide operating temperature range from -40 to 85 °C
HUR128
- 8 Channel 5Amps 250VAC/30VDC Digital Relay Output
- 5-48V (max. 60V) DC wide range power input
- Device Address changeable with Modbus RTU commands
- Output Values can be saved and Applied After Auto Restart
- Output Configuration for device power up can be defined by user with Modbus Commands
- Easy to Monitor Device Parameters such as Device Up Time, Modbus RTU read counter etc. with Modbus Commands
- Supports Modbus RTU Protocol over RS485 with 115200 8N1 Data Type
- Easy Firmware Upgrade over Serial Line
- Wide operating temperature range from -40 to 85 °C
HUR318
- 8 Channel 12-275V AC-DC, 60mA Digital Optocoupler Input
- 5-48V (max. 60V) DC wide range power input
- Device Address changeable with Modbus RTU commands
- Easy to Monitor Device Parameters such as Device Up Time, Modbus RTU read counter etc. with Modbus Commands
- Supports Modbus RTU Protocol over RS485 with 115200 8N1 Data Type
- Easy Firmware Upgrade over Serial Line
- Wide operating temperature range from -40 to 85 °C
HUR518
- 8 Channel 0-10V and 0-20mA Selectable Analog Input
- 5-48V (max. 60V) DC wide range power input
- Device Address changeable with Modbus RTU commands
- Easy to Monitor Device Parameters such as Device Up Time, Modbus RTU read counter etc. with Modbus Commands
- Supports Modbus RTU Protocol over RS485 with 115200 8N1 Data Type
- Easy Firmware Upgrade over Serial Line
- Wide operating temperature range from -40 to 85 °C
HUR555
- 5 Channel 4-20mA Analog Output
- 5-48V (max. 60V) DC wide range power input
- Device Address changeable with Modbus RTU commands
- Output Values can be saved and Applied After Auto Restart
- Output Configuration for device power up can be defined by user with Modbus Commands
- Easy to Monitor Device Parameters such as Device Up Time, Modbus RTU read counter etc. with Modbus Commands
- Supports Modbus RTU Protocol over RS485 with 115200 8N1 Data Type
- Easy Firmware Upgrade over Serial Line
- Wide operating temperature range from -40 to 85 °C
HUR158
- 8 Channel 5-275V AC-DC, 100mA Digital Optocoupler Output
- 5-48V DC wide range power input (allows up to 60 V DC)
- Supports 2 x 10/100Base-T(X) ports
- Supports 1 x RS232 and 1 x RS485 Serial Connection up to 921600 Baud
- Embedded web interface for ease of use
- Device Address changeable via web interface
- Modbus TCP to RTU Gateway functionality for Modbus packages with different addresses (Different than device own address)
- Output configuration can be defined by user for restart
- Output values can be saved and applied during auto restart
- I/O Mirror functionality: Device can duplicate output from a Modbus input device
- Easy to follow Device Parameters such as Device Up Time, Modbus read counter etc. on web interface
- Easy to follow Serial and Ethernet data packages on web interface
- Black List and White List based IP Filter in TCP Server Mode
- Firmware Upgrade over Web
- Wide operating temperature range from -40 to 85 °C
HUR168
- 8 Channel 5Amps 250VAC/30VDC Digital Relay Output
- 5-48V DC wide range power input (allows up to 60 V DC)
- Supports 2 x 10/100Base-T(X) ports
- Supports 1 x RS232 and 1 x RS485 Serial Connection up to 921600 Baud
- Embedded web interface for ease of use
- Device Address changeable via web interface
- Modbus TCP to RTU Gateway functionality for Modbus packages with different addresses (Different than device own address)
- Output configuration can be defined by user for restart
- Output values can be saved and applied during auto restart
- I/O Mirror functionality: Device can duplicate output from a Modbus input device
- Easy to follow Device Parameters such as Device Up Time, Modbus read counter etc. on web interface
- Easy to follow Serial and Ethernet data packages on web interface
- Black List and White List based IP Filter in TCP Server Mode
- Firmware Upgrade over Web
- Wide operating temperature range from -40 to 85 °C
HUR358
- 8 Channel 12-275V AC-DC, 60mA Digital Optocoupler Input
- 5-48V DC wide range power input (allows up to 60 V DC)
- Supports 2 x 10/100Base-T(X) ports
- Supports 1 x RS232 and 1 x RS485 Serial Connection up to 921600 Baud
- Embedded web interface for ease of use
- Device Address changeable via web interface
- Modbus TCP to RTU Gateway functionality for Modbus packages with different addresses (Different than device own address)
- Easy to follow Device Parameters such as Device Up Time, Modbus read counter etc. on web interface
- Easy to follow Serial and Ethernet data packages on web interface
- Black List and White List based IP Filter in TCP Server Mode
- Firmware Upgrade over Web
- Wide operating temperature range from -40 to 85 °C
HUR558
- 8 Channel 0-10V and 0-20mA Selectable Analog Input
- 5-48V DC wide range power input (allows up to 60 V DC)
- Supports 2 x 10/100Base-T(X) ports
- Supports 1 x RS232 and 1 x RS485 Serial Connection up to 921600 Baud
- Embedded web interface for ease of use
- Device Address changeable via web interface
- Modbus TCP to RTU Gateway functionality for Modbus packages with different addresses (Different than device own address)
- Easy to follow Device Parameters such as Device Up Time, Modbus read counter etc. on web interface
- Easy to follow Serial and Ethernet data packages on web interface
- Black List and White List based IP Filter in TCP Server Mode
- Firmware Upgrade over Web
- Wide operating temperature range from -40 to 85 °C
HUR595
- 5 Channel 4-20mA Analog Output
- 5-48V DC wide range power input (allows up to 60 V DC)
- Supports 2 x 10/100Base-T(X) ports
- Supports 1 x RS232 and 1 x RS485 Serial Connection up to 921600 Baud
- Embedded web interface for ease of use
- Device Address changeable via web interface
- Modbus TCP to RTU Gateway functionality for Modbus packages with different addresses (Different than device own address)
- Output configuration can be defined by user for restart
- Output values can be saved and applied during auto restart
- I/O Mirror functionality: Device can duplicate output from a Modbus input device
- Easy to follow Device Parameters such as Device Up Time, Modbus read counter etc. on web interface
- Easy to follow Serial and Ethernet data packages on web interface
- Black List and White List based IP Filter in TCP Server Mode
- Firmware Upgrade over Web
- Wide operating temperature range from -40 to 85 °C
HUR711
- 4 Slots x 8 Channel 5-275V AC-DC, 100mA Digital Optocoupler Output
- 5-48V DC wide range power input (allows up to 60 V DC)
- Supports 2 x 10/100Base-T(X) ports
- Embedded web interface for ease of use
- Device Address changeable via web interface
- Output configuration can be defined by user for restart
- Output values can be saved and applied during auto restart
- I/O Mirror functionality: Device can duplicate output from a Modbus input device
- Easy to follow Device Parameters such as Device Up Time, Modbus read counter etc. on web interface
- Easy to follow Serial and Ethernet data packages on web interface
- Black List and White List based IP Filter in TCP Server Mode
- Firmware Upgrade over Web
- Wide operating temperature range from -40 to 85 °C
HUR712
- 4 Slots x 8 Channel 5Amps 250VAC/30VDC Digital Relay Output
- 5-48V DC wide range power input (allows up to 60 V DC)
- Supports 2 x 10/100Base-T(X) ports
- Embedded web interface for ease of use
- Device Address changeable via web interface
- Output configuration can be defined by user for restart
- Output values can be saved and applied during auto restart
- I/O Mirror functionality: Device can duplicate output from a Modbus input device
- Easy to follow Device Parameters such as Device Up Time, Modbus read counter etc. on web interface
- Easy to follow Serial and Ethernet data packages on web interface
- Black List and White List based IP Filter in TCP Server Mode
- Firmware Upgrade over Web
- Wide operating temperature range from -40 to 85 °C
HUR713
- 4 Slots x 8 Channel 12-275V AC-DC, 60mA Digital Optocoupler Input
- 5-48V DC wide range power input (allows up to 60 V DC)
- Supports 2 x 10/100Base-T(X) ports
- Embedded web interface for ease of use
- Device Address changeable via web interface
- Easy to follow Device Parameters such as Device Up Time, Modbus read counter etc. on web interface
- Easy to follow Serial and Ethernet data packages on web interface
- Black List and White List based IP Filter in TCP Server Mode
- Firmware Upgrade over Web
- Wide operating temperature range from -40 to 85 °C
HUR714
- 4 Slots x 8 Channel 0-20mA Analog Input
- 5-48V DC wide range power input (allows up to 60 V DC)
- Supports 2 x 10/100Base-T(X) ports
- Embedded web interface for ease of use
- Device Address changeable via web interface
- Easy to follow Device Parameters such as Device Up Time, Modbus read counter etc. on web interface
- Easy to follow Serial and Ethernet data packages on web interface
- Black List and White List based IP Filter in TCP Server Mode
- Firmware Upgrade over Web
- Wide operating temperature range from -40 to 85 °C
HUR715
- 4 Slots x 5 Channel 4-20mA Analog Output
- 5-48V DC wide range power input (allows up to 60 V DC)
- Supports 2 x 10/100Base-T(X) ports
- Embedded web interface for ease of use
- Device Address changeable via web interface
- Output configuration can be defined by user for restart
- Output values can be saved and applied during auto restart
- I/O Mirror functionality: Device can duplicate output from a Modbus input device
- Easy to follow Device Parameters such as Device Up Time, Modbus read counter etc. on web interface
- Easy to follow Serial and Ethernet data packages on web interface
- Black List and White List based IP Filter in TCP Server Mode
- Firmware Upgrade over Web
- Wide operating temperature range from -40 to 85 °C
HUR721
- 2 x 8 Channels 5-275V AC-DC, 100mA Digital Optocoupler Output
- 2 x 8 Channels 12-275 AC-DC, 60mA Digital Optocoupler Input
- 5-48V DC wide range power input (allows up to 60 V DC)
- Supports 2 x 10/100Base-T(X) ports
- Embedded web interface for ease of use
- Device Address changeable via web interface
- Output configuration can be defined by user for restart
- Output values can be saved and applied during auto restart
- I/O Mirror functionality: Device can duplicate output from a Modbus input device
- Easy to follow Device Parameters such as Device Up Time, Modbus read counter etc. on web interface
- Easy to follow Serial and Ethernet data packages on web interface
- Black List and White List based IP Filter in TCP Server Mode
- Firmware Upgrade over Web
- Wide operating temperature range from -40 to 85 °C
HUR722
- 2 x 8 Channels Digital 5Amps 250VAC/30VDC Relay Output
- 2 x 8 Channels 12-275 AC-DC, 60mA Digital Optocoupler Input
- 5-48V DC wide range power input (allows up to 60 V DC)
- Supports 2 x 10/100Base-T(X) ports
- Embedded web interface for ease of use
- Device Address changeable via web interface
- Output configuration can be defined by user for restart
- Output values can be saved and applied during auto restart
- I/O Mirror functionality: Device can duplicate output from a Modbus input device
- Easy to follow Device Parameters such as Device Up Time, Modbus read counter etc. on web interface
- Easy to follow Serial and Ethernet data packages on web interface
- Black List and White List based IP Filter in TCP Server Mode
- Firmware Upgrade over Web
- Wide operating temperature range from -40 to 85 °C
HUR725
- 2 x 5 Channels 4-20mA Analog Output
- 2 x 8 Channels 0-20mA Analog Input
- 5-48V DC wide range power input (allows up to 60 V DC)
- Supports 2 x 10/100Base-T(X) ports
- Embedded web interface for ease of use
- Device Address changeable via web interface
- Output configuration can be defined by user for restart
- Output values can be saved and applied during auto restart
- I/O Mirror functionality: Device can duplicate output from a Modbus input device
- Easy to follow Device Parameters such as Device Up Time, Modbus read counter etc. on web interface
- Easy to follow Serial and Ethernet data packages on web interface
- Black List and White List based IP Filter in TCP Server Mode
- Firmware Upgrade over Web
- Wide operating temperature range from -40 to 85 °C
HUR741
- 1 x 5 Channels 4-20mA Analog Output
- 1 x 8 Channels Digital 5Amps 250VAC/30VDC Relay Output
- 1 x 8 Channels 0-20mA Analog Input
- 1 x 8 Channels 12-275 AC-DC, 60mA Digital Optocoupler Input Modbus TCP Remote IO Device
- 5-48V DC wide range power input (allows up to 60 V DC)
- Supports 2 x 10/100Base-T(X) ports
- Embedded web interface for ease of use
- Device Address changeable via web interface
- Output configuration can be defined by user for restart
- Output values can be saved and applied during auto restart
- I/O Mirror functionality: Device can duplicate output from a Modbus input device
- Easy to follow Device Parameters such as Device Up Time, Modbus read counter etc. on web interface
- Easy to follow Serial and Ethernet data packages on web interface
- Black List and White List based IP Filter in TCP Server Mode
- Firmware Upgrade over Web
- Wide operating temperature range from -40 to 85 °C
And what about LORAWAN?
For all modules of the HUR7xx and HUR8xx series, there are corresponding LoRaWAN versions: same number of inputs and outputs and in addition the LoRaWAN module that allows to transmit the status of inputs and outputs and control them via LoRaWAN protocol. The LoRaWAN product codes differ only by the digit "1" after the HUR codePer esempio
HUR711 (modbus) ==> HUR1711 (LoRaWAN)
HUR721 (modbus) ==> HUR1721 (LoRaWAN)
They are UNIQUE products in the LoRa world, both in terms of their extremely competitive price compared to the competition and the number of I/O present.
For more information, please visit the manufacturer's page (https://redz-sc.com/en/product/hur-series-modbus-tcp-and-rtu-remote-io-devices-with-mqtt-and-lorawan) or contact us for complete datasheets and a dedicated offer.