Description
Marcom OPC Server S7.Net is an OPC Server for communicating with Siemens© PLCs. S7-200™, S7-300™, S7-400™, S7-1200™, S7-1500™ and LOGO™, SINVERT™ inverters over Ethernet network!
A latest-generation OPC Server ideal for monitoring three-phase solar inverters model Siemens Sinvert™..
Marcom OPC Server S7.Net offers high performance and great ease of use. As a leader in the supply of OPC products, Marcom is proud to distribute the clearly best product on the market for OPC products for communication with the Siemens world:
- Very high performance: communication over Ethernet network allows achieving very high data exchange speeds
- Simple and immediate configuration: guarantees very high commissioning speed
- Extremely convenient: a sizing system to adapt to any need
Marcom OPC Server S7.Net allows fast and comfortable access to process data in S7-200 (via CP-243), S7-300, S7-400, S7-1200, S7-1500 and LOGO controllers, using a single server. Variables are constantly addressed using the STEP7 semantics specific to Siemens development environments.
With any client application that is compatible with OPC specifications, all input and output data, datablocks and markers can be read and written. Simultaneous access to an unlimited number of controllers is possible.
For communication with Marcom OPC Server S7.Net it is not necessary to modify the program. Access to controllers can be done directly via Ethernet.
An intelligent algorithm for managing read and write requests optimizes data throughput extremely efficiently: block reading allows unparalleled data refresh.
Configuration is done through a convenient graphical interface, in manual mode or thanks to a tool for importing symbolic names from STEP7 projects, Excel files or .db files exported directly from TIA Portal. Existing configurations can, for example, be exported to Excel from visualization or process control systems to be conveniently uploaded to Marcom OPC Server S7.Net.
The main features of the OPC Server are:
| Connection/Connections | Access to process data of S7-300, S7-400, S7-1200, S7-1500 and LOGO PLCs via Ethernet Redundant access for S7-400H systems |
| Supported Data Types | BOOL, BYTE, WORD, INT, DWORD, DINT, REAL, TIME, TIMER, COUNTER, Byte Array, Word Array, Int Array, Float/Real Array |
| Dynamic Variable Support | Creation/deletion of variables from OPC client with Siemens OPC Server syntax. This option must be ordered separately in the license |
| Configuration |
|
| OPC Specification | Compliant with OPC Data Access 2.04 specification |
| OPC Interfaces |
|
| Supported Operating Systems | Windows 7/8/10/11 (32 bit and 64 bit) + .NET Framework 4.6.2. |
| Multilingual Support | Italian and English with online HELP |
MPI-Ethernet gateway available that allows use also with PLCs equipped with only the MPI port.
Works transparently on the MPI port using the gateways: NL50MPI Hilscher, NETLink PRO by Helmholz, NETLink PRO by Softing.
For more information visit the OPC Support